Zengin データ record — one transfer in a Japanese bank transfer file
One 120 byte Data record expresses a transfer instruction inside a company-to-bank general-transfer file. Use the contracted bank’s current layout; the similar Zengin name does not make this a Zengin-Net interbank message or a settlement instruction.
DIRECTION: A company sends a bank-specific general-transfer instruction file to its contracted sending bank. That company-to-bank upload is a different interface from Zengin-Net interbank processing and BOJ-NET settlement. The receiving-bank fields identify intended destinations; the uploaded line is not itself a completed transfer or settlement result.
WHO IS INVOLVED
- 委託者 (itakusha) — the company asking for the transfersProduces the company-to-bank instruction file using the contracted provider profile and its assigned company/account details. It retains authorisation and reconciliation evidence outside the positional file.
- 仕向金融機関 (shimuke kin-yū kikan) — the sending bankValidates the actual upload against its service/profile and customer conditions. Acceptance, debit, interbank processing and settlement are separate results; the raw upload does not prove them.
- 被仕向金融機関 (hishimuke kin-yū kikan) — the receiving bankIs identified by the receiving institution/branch/account fields. Actual validation and crediting follow applicable provider/interbank rules, not a promise that every syntactically valid row can be applied.
- 受取人 (uketorinin) — the payeeIs represented by the prescribed account and name fields. A name in the file neither authenticates the payee nor establishes that the bank performs no name/account validation.
WHAT TO UNDERSTAND ABOUT IT
This page annotates the actual Gunma Bank public profile and shows its field positions, constants andEDI switch. The paired frame page supplies the header, trailer and end-record layout. An optionalCRLF terminator is outside the 120 byte record content.
Version + profile: Zengin データ is a fixed-width layout, so a field is found by counting characters and a layout version is not cosmetic: when a publisher revises the document, positions move and a reader that counts to the old offset reads the wrong field rather than failing. Check the version your counterparty is sending before building against this page, and check whether they have a house variant — several of these formats are published as a standard that banks are free to extend.